Quality & TestingSeptember 7, 2026 · 5 min read

How to read a certificate of analysis

What HPLC purity, retention time, mass spectrometry, peptide content, counter-ions, and water content really tell you, plus the warning signs that deserve a closer look.

By Kestrel Peptides team

Quality & Testing

A certificate of analysis, or COA, is the link between the label on a vial and what is actually inside it. It summarizes the analytical tests performed on a specific production lot, and a few minutes spent reading one carefully can tell you whether a peptide is what it claims to be, how pure it is, and how much of the powder is peptide at all. This guide walks through the sections you will typically find and how to interpret each one.

What a COA is, and what it is not

A COA is a batch-specific record. Its results describe one lot, tested at one point in time, using stated methods. It is not a general specification sheet, and the results for one lot say nothing definitive about another.

The header: identity and traceability

Start at the top. You should find:

  • the product name and, for peptides, the amino acid sequence or structure
  • the molecular formula and expected molecular weight
  • a lot or batch number
  • the date of analysis
  • the testing laboratory and an authorizing signature or approval

The lot number is the most important detail on the page. It should match the lot number on your vial or its packaging. A COA for a different lot, however good its numbers, does not describe the material in your hands.

HPLC purity

High-performance liquid chromatography (HPLC) is the standard method for measuring peptide purity. In reversed-phase HPLC, a solvent gradient carries the sample through a column, and components separate according to how strongly they interact with the column's hydrophobic stationary phase. A UV detector, usually set near the wavelength at which peptide bonds absorb, records each component as a peak as it elutes.

Peak area

Purity is usually reported as area percent: the area of the main peak divided by the total area of all integrated peaks, multiplied by 100. A result of 99% means that 99% of the UV-absorbing material detected under those conditions eluted as the main peak.

Two limits follow from how the measurement works. It describes relative purity among detected species only, so water, salts, and counter-ions are not counted. And it depends on the method, so purity figures from different laboratories or gradients are not always directly comparable.

Retention time

Retention time is the point at which a peak elutes, measured in minutes from the start of the run. It depends on the column, gradient, mobile phase, flow rate, and temperature, so it is meaningful for comparing samples run under the same method, not across methods. Retention time alone does not prove identity, because different molecules can elute at similar times. That is the job of mass spectrometry.

Reading the chromatogram

A strong COA includes the chromatogram itself, not just a percentage. Look for one dominant peak on a stable baseline, with any minor peaks small and clearly integrated. In synthetic peptides, minor peaks commonly reflect closely related impurities, such as sequences missing a residue, truncated chains, incompletely deprotected side chains, or oxidized forms.

Mass spectrometry: confirming identity

Mass spectrometry measures the mass-to-charge ratio (m/z) of ionized molecules. For peptides, it answers the most basic question a COA can address: is this the right molecule?

Expected versus observed mass

The expected mass is calculated from the sequence and any modifications; the observed mass is what the instrument measured. The two should agree within the accuracy expected for the instrument. Check whether the report uses monoisotopic or average mass, since they differ, and compare like with like.

Electrospray ionization, a common technique, often produces multiply charged ions. A peptide with a mass of about 3,000 Da might appear as peaks near 1,500 and 1,000 m/z, its doubly and triply charged forms. The software deconvolutes these into a single neutral mass, or the report lists the charge states so you can check the arithmetic yourself.

Common small differences

Some deviations from the expected mass are informative rather than alarming:

  • +22 Da usually indicates a sodium adduct formed during ionization, not a separate impurity.
  • +16 Da suggests oxidation, most often of methionine, and is worth noting if it appears as a significant species.
  • +1 Da can reflect deamidation of asparagine or glutamine.
  • A mass lower by one residue's weight points to a deletion sequence.

Mass spectrometry confirms identity; it does not measure purity. You need both results, because each covers the other's blind spot.

Peptide content versus purity

These two figures are often confused, and they answer different questions.

  • Purity is the fraction of the peptide-related material that is the target sequence.
  • Peptide content, or net peptide content, is the fraction of the total powder mass that is peptide.

Lyophilized peptides are isolated as salts and retain some water, so part of the mass of any vial is counter-ions and moisture. A peptide can therefore be 99% pure by HPLC while its net peptide content is well below 100%. Both statements are true at once. Peptide content is measured by methods such as amino acid analysis or nitrogen determination, and it matters most when you calculate solution concentrations for quantitative work.

Counter-ions: TFA and acetate

Basic residues such as lysine, arginine, and histidine, along with a free N-terminus, carry positive charges that pair with counter-ions. Trifluoroacetic acid (TFA) is widely used in peptide synthesis and HPLC purification, so many peptides are isolated as TFA salts. Some are converted to acetate or hydrochloride salts, often because residual TFA can interfere with certain cell-based assays. A COA may state the salt form or report counter-ion content; if your work is sensitive to TFA, confirm it before you begin.

Water content

Lyophilized material is hygroscopic and retains some residual moisture. Water content is commonly measured by Karl Fischer titration and reported as a percentage of mass. Higher water content lowers the amount of peptide per milligram of powder and can contribute to degradation over time, which is one reason storage conditions matter.

Red flags

Most COAs are straightforward. A few patterns deserve a closer look:

  • no lot number, or a lot number that does not match your vial
  • a purity figure with no chromatogram, or an identity claim with no mass data
  • no stated method, test date, or testing laboratory
  • an observed mass that does not match the expected mass and is not explained by a common adduct
  • identical chromatograms, down to the baseline noise, presented for different lots or products
  • a purity of exactly 100%, or dates that do not follow a logical order
  • signs of editing, such as mismatched fonts or misaligned values

If something looks inconsistent, ask the supplier. A clear, specific answer is itself a good sign.

A quick reading routine

  1. Match the lot number to your vial.
  2. Confirm identity by comparing observed and expected mass.
  3. Check the purity figure against the chromatogram.
  4. Note the salt form and peptide content for concentration calculations.
  5. Confirm the test date and laboratory details.

We publish a certificate of analysis for each batch where available, and the COA for any batch can be requested by email. All of our products are supplied for in-vitro laboratory research only.

This article is for educational and laboratory-research purposes only. Nothing here is medical advice, and no product sold by Kestrel Peptides is intended for human or veterinary use.

Compounds mentioned

BPC-157 vial

Regenerative Research

BPC-157

Body Protection Compound-157

From$26.00

2 mg · 5 mg · 10 mg · 20 mg

per box (10 vials) · 20 box

Ipamorelin vial

GH Secretagogues

Ipamorelin

Selective ghrelin-receptor agonist

From$32.00

2 mg · 5 mg · 10 mg

per box (10 vials) · 20 box

TB-500 vial

Regenerative Research

TB-500

Thymosin Beta-4

From$46.00

2 mg · 5 mg · 10 mg

per box (10 vials) · 20 box

Thymosin Alpha-1 vial

Immunomodulatory

Thymosin Alpha-1

Thymalfasin

From$108.00

5 mg · 10 mg

per box (10 vials) · 20 box